The SIGMATWIN double-wall plate heat exchanger has been specifically designed to meet specific requirements for a heat exchanger as a safety plate.
Contruction and Functional Concept
Instead of a single SIGMA plate we apply a SIGMATWIN plate pair, which has been moulded together and put into each other. The sealing of the gap is realised with flat ring gaskets or laser welded.
This prevents a contamination of the two fluids / products which are engaged in the heat exchange process in the event of a leakage. A leakage escapes into the gap between the two plates and can be seen during an inspection.
SIGMA plate heat exchangers equipped with SIGMATWIN double-wall plates can be opened like standard plate heat exchangers for inspection, or maintenance purposes.
Specifications
- Applicable for volume flow rates up to 320 m3/h
- Plate thickness of the SIGMATWIN double-wall plates
- 2 x 0,3 mm or 2 x 0,4 mm
- Stainless steel 1.4404 and others
- Elastomer gaskets NBR / EPDM (FDA-compliant)
SigmaTwin Series Numbers
- SIGMATWIN M7 DW
- SIGMATWIN M9 DW
- SIGMATWIN M26 DW
- SIGMATWIN M37 DW
- SIGMATWIN M66 DW